Customization: | Available |
---|---|
Usage: | Signal Jammer |
Type: | Wireless |
Still deciding? Get samples of US$ 1900/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item
|
Parameter
|
Remark
|
|||
working frequency
|
20M-6000M
|
|
|||
power
|
100W
|
|
|||
Operating Voltage
|
28V
|
24-36V
|
|||
Conversion efficiency
|
≥42%
|
@100W
|
|||
Adjustable output power
|
10W~100W
|
Software set power
|
|||
ALC power adjustment range
|
≥20dB
|
Voltage Controlled Attenuation
|
|||
gain
|
48±1.0dB
|
|
|||
In-band fluctuation
|
≤2.5dB
|
peak
|
|||
spurious emissions
|
In working band
|
≤-15dBm/1MHz
|
Measured when the center frequency plus CW signal to the maximum output power
|
||
|
Out-of-band
|
9KHz~1GHz
|
No higher than normal noise floor clutter
|
|
|
|
|
1G~12.75GHz
|
|
|
|
Maximum allowable input power
|
≥+10dBm
|
Lasts 1min without damage
|
|||
Input VSWR
|
≤1.35
|
Add +28V, standard network output -10dBm
|
|||
Output VSWR
|
≤1.35
|
No power, standard network output -10dBm
|
|||
|
≤1.35
|
Power On, Dual Directional Coupler Test
|
|||
High and low temperature test
|
Working environment temperature (ºC)
|
-10~+65ºC
|
Low temperature can start, monitoring works normally
|
||
|
Gain Stability
|
±1.5dB @-40ºC~+65ºC
|
|
||
|
power stability
|
±1dB @-40ºC~+65ºC
|
|
||
Power Requirements
|
≥8A @+28Vdc;
|
CW output 100W
|
|||
Power supply interface, communication interface RS485
|
7W2
|
Male, 1:485A; 2:485B
|
|||
RF output connector
|
N-Female connector
|
||||
with 3 LED lights
|
POWER: Power indication; RUN: Running indication; ALARM: Alarm indication;
|
||||
physical dimension
|
700M-6G:155*125*26mm; 20M-500M:155*125*35mm
|
||||
weight
|
<1Kg
|
||||
Appearance (how to use)
|
Signal source power amplifier integrated module (fixed on the radiator)
|
Monitoring Function
|
Description
|
Remark
|
|
Amplifier part setting parameters
|
Amplifier switch
|
Turn the amplifier on or off
|
|
|
Alarm switch
|
Enable and disable the alarm function
|
|
|
Downlink Power Control
|
The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power
levels can be set |
|
|
Amplifier over temperature alarm
|
The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will
automatically shut down; 65 degrees will automatically restore |
|
|
Amplifier overpower alarm
|
The actual power value is 2dB higher than the downlink ALC start control threshold and close
|
|
|
Power amplifier standing wave alarm
|
When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off
|
|
|
Amplifier overcurrent alarm
|
When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off
|
|
|
Amplifier under-power alarm
|
When the power amplifier detection power is less than 33dBm, an under-power alarm is displayed
|
|
|
Amplifier overvoltage alarm
|
When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down
|
|
|
Amplifier undervoltage alarm
|
Amplifier voltage <20V displays under-voltage alarm
|
|
Amplifier part query parameters
|
Amplifier switch status
|
If the power amplifier is set to "OFF", the query should be the state of power amplifier off state; otherwise, it is the open
power amplifier state |
|
|
Downstream output power level value
|
Detect power amplifier output power value, detection range (Pomax+2, Pomax-20)
|
Detection accuracy: Pout±1dB
|
|
Downward standing wave ratio
|
The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0
|
|
|
temperature query
|
Detect the internal temperature of the module, detection range: -40ºC~+100ºC
|
Detection error: ±3ºC
|
|
ALC value query
|
The displayed value is equal to the actual set ALC value
|
|
|
Voltage detection
|
Detection module working voltage
|
|
|
Current Detection
|
Detection module operating current
|
|
Signal generator settings
|
Frequency setting mode 1
|
Any single frequency point setting within the range
|
The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G
|
|
Frequency setting mode 2
|
Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set
|
|
|
Frequency setting mode 3
|
Set any 4 sub-frequency segments within the bandwidth, and the sub-segments are incremented
|
|
Module Communication Protocol
|
RS485
|
|
|
Interface definition
|
+:28V,-: GND; 1:485A,2:485B
|