Customization: | Available |
---|---|
Usage: | Signal Jammer |
Type: | Wireless |
Still deciding? Get samples of US$ 1800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Parameter | Unit | Remarks | |||
Operating Voltage | 28 | V | 24-30V | |||
Conversion efficiency | ≥42% | % | @100W typical | |||
Controllable output power | 10W~100W | W | Software set power level | |||
ALC power adjustment range | ≥30 | dB | Voltage Controlled Attenuation | |||
gain | 50±1.0 | dB | ||||
In-band fluctuation | ≤2.5 | dB | peak-to-peak | |||
spurious emission |
In working band | ≤-15dBm/1MHz | dBm | Measured when the center frequency plus CW signal to the maximum output power | ||
out of work band | 9KHz~1GHz | No higher than normal noise floor clutter | dBm | |||
1G~12.75GHz | dBm | |||||
Maximum allowable input power | ≥+10dBm | dBm | Lasts 1min without damage | |||
Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | ||||
Output VSWR | ≤1.30 | No power, standard network output -10dBm | ||||
≤1.35 | Power On, Dual Directional Coupler Test | |||||
High and low temperature test | Working ambient temperature (ºC) | -10~+65 | ºC | Low temperature can start, monitoring works normally | ||
Gain Stability | ±1.5 @-40ºC~+65ºC | dB | ||||
power stability | ±1 @-40ºC~+65ºC | dB | ||||
Power Requirements | ≥8A @+28Vdc; | CW output 100W | ||||
Power supply interface, monitoring interface RS485 | 7W2 | Male | ||||
RF output connector | N-F connector | |||||
LCD liquid crystal display | Display frequency, power, switch status | |||||
with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | |||||
Built-in cooling fan | Modules can be run separately | |||||
physical dimension | 155 x 125 x 60mm | |||||
Weight | 1.6Kg | |||||
Appearance (how to use) | Black integrated module with fan (single or portable use) |
Monitoring | Function Description | Remarks | |
Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
Alarm switch | Enable and disable the alarm function | ||
Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
Amplifier under-power alarm | When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed | ||
Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on. | |
Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy:Pout±1dB | |
Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
temperature query | Detect the internal temperature of the module, detection range: -40ºC~+100ºC | detection error:±3ºC | |
ALC value query | The displayed value is equal to the actual set ALC value | ||
Voltage detection | Detection module working voltage | ||
Current Detection | Detection module operating current | ||
Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented | ||
module communication | RS485 | ||
Interface definition | +:28V,-: GND; control bit 1:485A,2:485B |