Element | Parameter | Unit | Notes | |||
Operating voltage | 28 | In | 24-30V | |||
Conversion efficiency | ≥42% | % | @100 Watts typical | |||
Controlled Power Output | 10W~100W | W | Software-defined power level | |||
ALC Power Adjustment Range | ≥30 | dB | Voltage-Controlled Attenuation | |||
increase | 50±1,0 | dB | ||||
Intraband Oscillation | ≤2,5 | dB | From peak to peak | |||
false outliers |
In the working group | ≤-15 dBm/1 MHz | Dbm | It is measured when the center frequency plus the CW signal reaches its maximum output power. | ||
Unemployedgroup | 9KHz~1GHz | The noise level is not higher than usual. | Dbm | |||
1G~12.75 GHz | Dbm | |||||
Maximum Allowable Input Power | ≥+10 dBm | Dbm | Lasts 1 minute without damage | |||
Input SWR | ≤1,35 | Add +28 V, standard -10 dBm mains output. | ||||
Output SWR | ≤1,30 | No power, standard mains output -10 dBm. | ||||
≤1,35 | Power on, bidirectional tap test | |||||
Highand lowtemperaturetest | Ambient Operating Temperature (°C) | -10~+65 | ºC | Low temperature may start, monitoring is working normally | ||
Get stability | ±1.5 at -40°C~+65°C | dB | ||||
Power Stability | ±1 at -40°C~+65°C | dB | ||||
Power Requirements | ≥8A @+28V DC; | CW 100W output power | ||||
Power supply interface, RS485 monitoring interface | 7W2 | Male | ||||
RF Output Connector | NFConnector | |||||
LCD LCD Display | Display of frequency, power, switch status | |||||
with 3 LED lights | POWER: Power indication; RUN: Operation Indication; ALARM: Alarm indication; | |||||
Built-in cooling fan | Modules can be run separately | |||||
Physical Dimension | 155 x 125 x 60 mm | |||||
Mass | 1.6 kg | |||||
Appearance (how to use) | Black built-in module with fan (single or portable use) |
Monitoring | Function Description | Remarks | |
Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
Alarm switch | Enable and disable the alarm function | ||
Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
Amplifier under-power alarm | When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed | ||
Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on. | |
Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy:Pout±1dB | |
Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
temperature query | Detect the internal temperature of the module, detection range: -40ºC~+100ºC | detection error:±3ºC | |
ALC value query | The displayed value is equal to the actual set ALC value | ||
Voltage detection | Detection module working voltage | ||
Current Detection | Detection module operating current | ||
Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented | ||
module communication | RS485 | ||
Interface definition | +:28V,-: GND; control bit 1:485A,2:485B |