900-1800MHz-100W Power Amplifier
Electrical performance indicators: | |
index | parameter |
Working frequency | 900MHz~1800MHz |
Gain | ≥50dB |
Input power | 3±1 dBm |
Maximum input | +10dBm |
Output CW saturated power | 100W |
In-band gain flatness | ≤3±1dB |
Temperature protection | 80 degree protection |
Poison working current | ≤11.5A |
Poison working current | ≤2.0 |
Clutter suppression | ≥65dBc |
Poison harmonic suppression | 2-13dBc |
RF input interface | SMA-F |
Chapter RF output interface | N-K |
28V power supply interface | through-core capacitor |
VCC power supply reference | 28-32V/16A |
VCC maximum voltage | +33V |
Overall dimensions excluding connectors | 238×128×25.3mm |
Operating temperature | -30ºC~+55ºC |
Installation method | A radiator needs to be installed for power amplifier testing |
Power supply,control interface 7W2 |
A1:VCC+28V; A2:GND
1:TEMP_AL: temperature alarm 2:RUN: Running instructions. Power, high level. No power, low level. 3: VSWR_AL:vswr alarm, high level alarm, low level elimination; 4:PA_EN : Enable switch; 5.PA_ADJ: NC |
Module protection | Temperature compensation, over temperature protection,vswr protection |
Signal source input | Built-in noise sweep signal source |
LED module indicator light | POWER: indicates the power supply indicator. RUN: indicates the power running indicator. VSWR: indicates the standing wave alarm indicator |
Power supply,control interface 7W2 |
A1:VCC+28V; A2:GND 1:TEMP_AL: temperature alarm 2:RUN: Running instructions. Power, high level. No power, low level. 3: VSWR_AL:vswr alarm, high level alarm, low level elimination; 4:PA_EN : Enable switch; 5.PA_ADJ: NC |
Module protection | Temperature compensation, over temperature protection,vswr protection |
Signal source input | Built-in noise sweep signal source |
LED module indicator light | POWER: indicates the power supply indicator. RUN: indicates the power running indicator. VSWR: indicates the standing wave alarm indicator |